7101 storing

Oorzaak

Aansluiting van incompatibele binnen- of buitendeel (verkeerde capaciteitscode).

Te controleren

Controleer de capaciteitscodes van de binnen- en buitendelen.
Op de binnendeel SW2 controleren.
Units die de storing kunnen veroorzaken:  

  • Buitendeel
  • Binnendelen
  • LOSSNAY

Capaciteit buitendeel

                                                                                    YNW-A
ModelSW5
 345678
P200OFFONOFFOFFONOFF
P250ONONOFFOFFONOFF
P300OFFOFFONOFFONOFF
P350OFFONONOFFONOFF
P400ONONONOFFONOFF
P450OFFOFFOFFONONOFF
P500ONOFFOFFONONOFF
P550OFFONOFFONONON
EP200OFFONOFFOFFONON
EP250ONONOFFOFFONON
EP300OFFOFFONOFFONON
EP350OFFONONOFFONON
EP400ONONONOFFONON
EP450OFFOFFOFFONONON
EP500ONOFFOFFONONON
EP550OFFONOFFONONON

Capaciteit binnendelen

Model                                                          SW2
 123456
P/M10OFFONOFFOFFOFFOFF
P/M15ONONOFFOFFOFFOFF
P/M20OFFOFFONOFFOFFOFF
P/M25ONOFFONOFFOFFOFF
P/M32OFFONONOFFOFFOFF
P/M40OFFOFFOFFONOFFOFF
P/M50OFFONOFFONOFFOFF
P/M63ONOFFONONOFFOFF
P/M71OFFONONONOFFOFF
P/M80OFFOFFOFFOFFONOFF
P/M100OFFOFFONOFFONOFF
P/M125ONOFFOFFONONOFF
P/M140OFFOFFONONONOFF
P/M200OFFOFFOFFONOFFON
P/M250OFFONOFFOFFONON